Step 4 Withdraw the turbulators from the
appliance. Carefully noting their condition and
position. Replace turbulators if necessary.
Step 5 The turbulators should be cleaned with
a soft brush.
Step 6 If required the interior of the tubes can
then be cleaned using an industrial vacuum
cleaner or by using long poles and a scraper.
Step 7 Refit components.
3.9 Heat Exchanger Servicing
Step 1 Remove the flue connections.
Step 2 Slacken casing support screws and
remove heat exchanger from the radiant tube.
Step 3 Remove any dust and dirt from the heat
exchanger & refit.
3.10 Reflector Servicing
The condition of the reflectors should be noted.
If necessary the reflectors can be cleaned with a
mild detergent.
This can significantly improve the efficiency of
the appliance.
3.11 Inspection of Flue
The flue needs to be inspected and cleaned if
necessary or in accordance to the regulations of
the country that the appliance is installed.
3.12 Re-commissioning After Service
After servicing of the heater has been
undertaken, it will be necessary to
re-commission the heater as detailed in Section
2 of these instructions.